v Dry cooler ma data center a ɛma onwini ano aduru .

Optimized for server cooling, saa dry cooler yi bɔ ho ban fi ɔhyew a ɛboro so ho. Aluminium microchannel coils ne high-Static-nhyɛso fan ahorow no hwɛ hu sɛ ɔhyew yiyi fi data center coolant loops mu yiye. Modular design no ma kwan ma seamless nkabom ne nsu cooling nhyehyɛe, di dwuma ɔhyew adesoa kosi 1 MW wɔ unit biara mu. Wɔ colocation facilities mu no, ɛhwɛ server inlet temperatures so wɔ 18-27℃, na esiw thermal throttling ne hardware a ɛsɛe no ano. Intelligent control system no sesa fan ahoɔhare a egyina server adesoa so, ɛtew ahoɔden a wɔde di dwuma so 40% sɛ wɔde toto mframa-nhyehyɛe a ɛyɛ nwini ho a. Ɛnam sɛ ɛyɛ corrosion-resistant finish ne IP65 rating nti, ɛyɛ adwuma a wotumi de ho to so wɔ mmeae a mfutuma anaa nsu a ɛyɛ nwini wɔ, na ɛtrɛw kɔmputa nhyehyɛe a ɛho hia no nkwa nna mu .
Aguade ho nsɛm .
Brand & Basic ho nsɛm .
◆ Brand:Hylita .
◆ Beae a wɔyɛ nneɛma:China .
◆ Adansedi nkrataa: CE, ISO 9001, Ashrae .
◆ Nhwɛsode: V{0}}DC-D1000 .
Nkitahodi & adetɔ ho nsɛm .
◆ Katua ho nsɛm: T/T (30% advance, 70% ansa na wɔde amena), L/C wɔ baabi a wohu .
◆ Minimum order quantity (MOQ): 1 unit (ketewa-batch sɔhwɛ a wɔboa; 5% a wɔatew so ama ahyɛde a ɛboro anaasɛ ɛne unit 5 yɛ pɛ) .
◆ bo a wɔbɔ:
Biako a ɛyɛ biako (1-4 units): $18,000-$22,000 (a egyina config so, a nyansa wom a wɔde di dwuma ka ho) .
Bulk order ( a ɛboro anaasɛ ɛne 5 units yɛ pɛ): $16,500-$20,000 (wɔasusuw ho ama dodow kɛse, a akwankyerɛ a wɔde besisi hɔ) .
Nneɛma a wɔde kyekyere nneɛma ho & nneɛma a wɔde kɔ .
◆ Nneɛma a wɔde kyekyere nneɛma ho:
Inner layer: EPE pearl cotton wrapping ma core components (aluminum heat exchangers, EC fans) na amma collision asɛe.
Outer layer: Export-Grade plywood crates (a ɛne ISPM 15 gyinapɛn ahorow hyia), nsu ntumi nkɔ mu na ɛyɛ nwini-adanse a ɛkyerɛ sɛ ɛpo/mframa de akwantu.
◆ Nneɛma a wɔde fa nnipa:
Ɔman no mu: Deppon/SF awɔw nkɔnsɔnkɔnsɔn (a ɛwɔ so-beae a wɔde si hɔ).
Amanaman ntam: DHL/Maersk, a ɛfoa CFR/FOB nsɛmfua so; Amannɔne adekoradan mu mmamu (nnafua 3 a wɔde kɔ Europa & Amerika).
◆ Bere a wɔde di kan:
Wɔ-Stock Models: Wɔde mena wɔ nnɔnhwerew 72 ntam.
Orders a wɔahyɛ da ayɛ: 15-25 adwuma nna (a ɛfa intelligent control functions & appearance customization ho).
Core product specifications .
|
Ɔfa |
Nkyerɛkyerɛmu . |
Nkyerɛmu |
|
Nneɛma a wɔde yɛ adwuma . |
Nsɛmma nhoma titiriw . |
Galvanized stainless steel (nkyene-a ɛyɛ den ma data center mmeae a atwa yɛn ho ahyia) . |
|
Ɔhyew a wɔde sesa nneɛma . |
Ahunmu-Aluminium microchannels a ɛyɛ fɛ (ɔhyew a ɛkɔ soro, emu yɛ hare) . |
|
|
Fans . |
EC variable-frequency fans (ahoɔden a wɔde di dwuma kakraa bi, ahoɔhare a ɛtrɛw nsakrae) . |
|
|
Tumi |
Fan tumi . |
200-800 W (wɔde nyansa sesa no denam mframa a ɛsen so; ɛba fam te sɛ 50 W wɔ adesoa biara so) . |
|
Muduro |
Net mu duru wɔ unit biara mu . |
350-500 kg (ɔhyew a egyina adesoa so; 1 MW nhwɛso bɛyɛ. 450 kg) . |
|
Nsusuwii . |
L×W×H |
2200×1500×2000 mm (1 MW mfonini, ɛboa modular stacking) . |
|
Application Fit . |
Ɔhyew adesoa a ɛkɔ soro . |
200 kW-1 MW/Unit (ɛboa multi-unit parallel ntrɛwmu) . |
|
Ɔhyew sohwɛ kwan . |
Coolant inlet: 15-35℃(Spably hwɛ server inlet so wɔ 18-27℃) . |
Core application scenarios .
◆ databea ahorow:
Colocation facilities: Ɛhwɛ server inlet temperature so pɛpɛɛpɛ (18{1}}27℃) a ɛbɛma wɔatumi asiw thermal throttling ano, a ɛfata ma racks a ɛwɔ ahoɔden kɛse (sɛ nhwɛso no, 42U blade server clusters).
Enterprise Server Rooms: Ɛne nsuo a ɛma onwini yɛ adwuma (sɛ nhwɛsoɔ no, awɔw mprɛte, nsuo a wɔde hyɛ mu a ɛma onwini) di nkitaho a biribiara nhaw no na ama AC nhyehyɛe ahoɔden a wɔde di dwuma no so atew.
◆ Edge Kɔmputa node ahorow:
Abɔnten/atwa yɛn ho ahyia a ɛyɛ hu: IP65-a wɔde atoto ho, a ɛko tia nsɛe no gyina mfutuma, nsu a ɛyɛ nwini, ne nsu nketenkete a wɔde petepete so (sɛ nhwɛso no, telecom base stations, industrial IoT hubs).
Dwumadi atitiriw .
◆ Ɔhyew a nyansa wom a wɔde di dwuma:
AI-Driven control system no sesa fan ahoɔhare a egyina ankasa-bere somfo adesoa so (ɛnam BMS/DCIM nkabom so), ɛtew ahoɔden a wɔde di dwuma so 40% vs. atetesɛm mframa-nhyehyɛe a ɛyɛ nwini.
Real-bere a wɔde hwɛ coolant a ɛsen, ɔhyew, ne fan tebea so, a alarm notifications ma anomalies (sɛ nhwɛso no, clogging, motor huammɔdi).
◆ Ɔsoro-Ɔhyew a wɔde sesa nneɛma yiye:
Aluminium microchannel coils nya ɔhyew a ɛkɔ soro kodu 600 W/(m2·k), ɔhyew a efi nsu mu-Server loops a ɛyɛ nwini (sɛ nhwɛso no, glycol-nsu a wɔde frafra).
High-Static-nhyɛ dan (airflow a ɛkɔ 8,000 m3/h) hwɛ hu sɛ mframa a ɛyɛ pɛ wɔ ɔhyew exchangers so, mpo wɔ soro-backpressure ducting setups.
Nneɛma a wɔde yɛ adwuma no mu mfaso .
◆ Ahoɔden a wɔkora so: 30-40% Ahoɔden a wɔde di dwuma no so tew denam nsakrae-Speed EC fan ne load-adaptive control so, a ɛkyerɛ ase kɔ $5,000-$8,000 afe biara a wɔkora so wɔ unit biara mu (wɔ $0.15/kWh).
◆ Modular Scalability: Hot-Modua a wotumi de di dwuma no ma kwan ma wotumi trɛw tumi a ɛkɔ soro (sɛ nhwɛso no, 200 kW nkɔanim) a nhyehyɛe no nkɔ so, a eye ma data mmeae a ɛrenyin.
◆ Ahotosoɔ wɔ mmeaeɛ a ɛyɛ den: IP65 ahobanbɔ ne nsuo a ɛbɛsɛe-ɛko tia adeɛ a ɛtumi gyina so ma ɛyɛ adwuma a ɛkɔ so wɔ mfuturo so server dan anaa abɔnten so (MTBF a ɛboro anaa ɛne no yɛ pɛ nnɔnhwereɛ 80,000).
◆ Ahunmu Optimization: 50% nan ase a ɛyɛ ketewa sen atetesɛm shell-ne-tube coolers, fitting into tight data center aisles anaa fam a ɛkorɔn.
◆ Nsiesiei a ɛba fam: Self-Nhwehwɛmu nhyehyɛe a wɔde di dwuma no brɛ nsaano nhwehwɛmu ase; Fan ne coil modules mmoa adwinnade-a wɔde besi ananmu a wontua hwee, bere a wɔde yɛ adwuma no so tew ( a ennu anaasɛ ɛne simma 30 yɛ pɛ wɔ module biara mu).
Tags a ɛyɛ hyew .: Injection Mold Cooling Dry Cooler, China Injection Mold Cooling Dry Cooler a Wɔyɛ, Wɔn a Wɔde Ma, Adwumayɛbea